A patient wearing a rotigotine transdermal patch is called for an urgent MRI. The patch is on intact skin and was applied two hours ago. What is the safest instruction?

Educational content. Not a substitute for clinical judgement or local policy.

Reveal the answer and explanation

Correct answer: ERemove it before MRI because its aluminium backing can heat and burn skin

Option E is correct: the Neupro backing contains aluminium and the patch must be removed before MRI or cardioversion to prevent a skin burn; subsequent dosing follows the prescribed plan. Option C invents a reservoir-only rule. Option B does not remove the conductive material. Option D merely changes its location. Option A deliberately retains the hazard and risks duplicate exposure.

Reference: Neupro SmPC: https://www.medicines.org.uk/emc/product/186/smpc