Instrument decontamination workflow — ORE Part 1 MCQ
Instant feedback + full explanation. One question, done properly.
Educational content. Not a substitute for clinical judgement or local policy.
Reveal the answer and explanation
Correct answer: C — To prevent processed instruments being recontaminated
Explanation lettering: B = shown as A · E = shown as B · D = shown as C · C = shown as D · A = shown as E
D is correct. A unidirectional dirty-to-clean workflow separates contaminated instruments from those that have completed decontamination, thereby reducing the opportunity for clean or sterilised instruments to be recontaminated. SDCEP describes decontamination as a staged process—cleaning, thermal disinfection, inspection and sterilisation—and requires procedures covering segregation after use and subsequent storage. It also advises that areas are clearly zoned as clean or dirty. A is incorrect because colour coding does not determine sterilisation efficacy. B reverses the segregation principle. C is wrong because wiping is not a substitute for validated cleaning and sterilisation processes. E is wrong because cleaning is an essential earlier stage before sterilisation and storage.
Reference: Scottish Dental Clinical Effectiveness Programme (SDCEP), Practice Support Manual, “Decontamination of dental instruments”, reviewed June 2026: https://www.psm.sdcep.org.uk/topics/infection-prevention-and-control/decontamination-of-dental-instruments/