Acrylate dermatitis — DOccMed MCQ
Instant feedback + full explanation. One question, done properly.
Educational content. Not a substitute for clinical judgement or local policy.
Reveal the answer and explanation
Correct answer: A — Skin surveillance with review of glove type, change frequency and acrylate exposure
Acrylates can cause allergic contact dermatitis, and ongoing skin surveillance is appropriate where exposure persists. Gloves may be inadequate if the material or change frequency is wrong. Surveillance should feed back into COSHH controls, training and substitution where feasible.
Reference: HSE Dermatitis Guidance; COSHH Regulations