Audiometric screening categorisation — DOccMed MCQ
Instant feedback + full explanation. One question, done properly.
Educational content. Not a substitute for clinical judgement or local policy.
Reveal the answer and explanation
Correct answer: A — Acceptable hearing with warning level pattern, counsel about hearing protection
A bilateral 4kHz dip is early NIHL. Under HSE HSG256, this is a warning level finding. The worker should be counselled and hearing protection reviewed.
Reference: HSE HSG256; Noise at Work Regs 2005