Doppler Assessment of AS - Window Selection — EECC MCQ
Instant feedback + full explanation. One question, done properly.
Educational content. Not a substitute for clinical judgement or local policy.
Reveal the answer and explanation
Correct answer: E — The right parasternal window often provides the most parallel alignment with the aortic jet, capturing the highest velocity and avoiding underestimation of the gradient that occurs with non-parallel Doppler angles
Accurate Doppler assessment of aortic stenosis requires the ultrasound beam to be as parallel as possible to the direction of blood flow through the stenotic valve (angle-dependent measurement). The right parasternal window (patient lying on right side) often provides the best alignment with the aortic jet axis, particularly in elderly patients where the aorta becomes more rightward. Using only the apical 5-chamber view may underestimate the true gradient by 10-30% if the beam-flow angle is suboptimal. The 2025 ESC VHD Guidelines and ASE/EACVI echo guidelines recommend interrogating the aortic valve from multiple windows (apical, right parasternal, suprasternal, subcostal) and reporting the highest velocity obtained.
Reference: ESC/EACTS (2025): VHD Guidelines; ASE/EACVI Echo Guidelines