Answer
Bexsero syringes may show a fine off-white deposit: shake well until homogeneous; inspect for particles/discoloration; do not use if foreign particles/appearance changes; if two needle lengths supplied, select for intramuscular use; hold barrel, not plunger; unscrew cap anticlockwise; lock needle hub onto Luer Lock Adaptor with ¼-turn clockwise; never withdraw plunger—if withdrawn, do not administer.
Sources for this answer
- Bexsero Meningococcal Group B vaccine for injection in pre-filled syringeGlaxoSmithKline UK · emc · SmPC §6.6 Special precautions for disposal and other handling · Version 25Document updated